DSN-1100-10 |
|
 |
|
The
D-Link® DSN-1100-10 xStack Storage 4x1GbE iSCSI SAN Array
provides a smaller, more value-oriented solution for entry-level
and SMB customers. The heart of the DSN-1100-10 is based on
the same powerful System-on-a-Chip (SoC) design found in larger
arrays such as the DSN-3000 Series of products, but housed in
a smaller chassis. Utilizing a 10Gbit iSCSI SoC solution that
can handle over 80,000 I/Os per second, the DSN-1100-10 is capable
of supporting 5TBs of raw capacity using 1TB hard drives (and
even higher capacity hard drives as they are introduced). The
DSN-1100-10 can easily |
be
implemented as nearline storage or as a supplement to your
primary backup and recovery device. This evolutionary advancement
in performance is a testament to the tightly integrated xStack
Storage architecture and is a sharp contrast to the discrete
implementation of competing products.
iSCSI for IP Networks
SAN has been traditionally reserved for Fibre Channel networks
until the recent introduction of iSCSI extended this powerful
yet simple centralized backend storage system to IP networks.
By utilizing existing Ethernet technology, the cost associated
with separate host bus adapters and the per-Gigabyte cost
for storage is significantly reduced. iSCSI SANs can leverage
the Ethernet infrastructure and standards that are already
familiar to your IT staff.
Four 1GbE Interfaces
The DSN-1100-10 implements four 1GbE ports that support IEEE
802.3ad Link Aggregation Groups (LAG) for full offload capability.
This allows all four ports to be grouped together for up to
425MB/s bandwidth, increasing throughput and redundancy.
System-on-a-Chip (SoC) Implementation
By utilizing a SoC design, the DSN-1100-10 combines both networking
and storage functions into a single specialized Application
Specific Integrated Circuit (ASIC). The SoC solution combines
10Gbps iSCSI, TCP & IP offload, embedded processors, and
storage virtualization firmware onto a single chip. The tight
integration of these functions eliminates interoperability,
timing, and support issues found in competitive products that
offer “discrete implementation” wherein all the
various components are chosen separately and then assembled.
The DSN-1100-10 outperforms these discrete implementations
and does so at a lower price point, while delivering mission-critical
data quickly with state-of-the-art reliability.
RAID for Efficiency
The DSN-1100-10 features five hot swappable Serial ATA (SATA)
disk drive bays supporting 5TB raw capacity using 1TB hard
drives (and even higher capacity hard drives as they are introduced)
in RAID level 0, 1, 1+0 and 5 configurations. You can quickly
deploy a SAN using inexpensive SATA disk drives and, depending
on your growing storage needs, you can simply add more drives
as you go.
Embedded Centralized Storage Management
The embedded, user-friendly IP-SAN Device Manager (IDM) provides
comprehensive network storage management. Boasting a rich
set of management features, this suite of utilities allows
monitoring and control of your SAN via the Storage Management
Initiative-Specification (SMI-S) command set. Combined with
an embedded secure server, users will be able to remotely
configure and monitor their SAN storage subsystems.
Advanced Management Features
The DSN-1100-10 provides additional advanced features for
efficient management of network storage and optimal performance.
For the fastest RAID performance offered in the industry,
the D-Link adaptive cache management provides write coalescing
and multi-stream read-ahead on a volume basis, optimizing
cache utilization and performance in an application-dependent
manner. Volatile cache data protection is afforded via an
on-board battery that is designed to back up to 1GB of cached
memory for at least 72 hours. A write-back or write-through
cache memory policy can be selected manually or automatically,
depending on the battery’s charge.
VLAN Zoning supports IEEE 802.1q VLAN tagging to segregate
traffic into isolated zones for secure access and jumbo frames,
improving network throughput and reducing CPU overhead.
Volume Virtualization utilizes the concept of storage Extents.
Extents are the fundamental building blocks used to enable
features such as RAID, online capacity expansion and volume
migration. Drives of dissimilar size can be used to create
volumes. Growth can occur without volume migration or reconstruction.
Single drives can contain multiple and divergent RAID technologies.
Volume structure can also provide infrastructure for Snapshot
copies.
RAID Support for RAID Levels 0, 1, 1+0 and 5 (striped sets,
mirrored sets, striped mirrored sets, and parity sets) allows
for different storage options.
Online Capacity Expansion and RAID Level Migration are performed
online with minimal impact on users. For example, a mirror
volume of two drives can easily be converted to a parity volume
of three or more drives while users continue to access this
storage.
Micro Rebuilds provide protection against unresponsive SATA
commands by forcing a response within a preset time limit.
An iSCSI array can prove to be a valuable tool to supplement
your network storage foundation. Whether providing a low-cost
block-based solution for data backup and recovery, replacement
of Direct-Attached Storage (DAS) drives, or providing a cost-effective
entry-level nearline storage solution, the DSN-1100-10 can
meet all of your immediate needs.
Technical
Specifications
|
Drive
Bays:
|
|
•
5 |
|
Drive
Interface Support:
|
•
SATA-II support |
|
System
Memory:
|
•
256MB to 512MB (256MB standard) |
|
Cache
Memory:
|
•
256MB to 1GB (256MB standard) |
|
Battery
Backup
for Cache:
|
•
Standard
(approximately 72 hours on full charge) |
|
Bandwidth:
|
•
Up to 425MB/s |
|
Storage
Capacity:
|
•
5TB capacity with 1TB hard drives
(supports for higher capacity drives as they
are introduced) |
|
Supported
NICs, iSCSI Accelerators
and iSCSI HBAs:
|
• Intel® Pro 1000MT & XT [1GbE]
• Intel Pro 10000 CX4 [10GbE]
• Myricom 10G-PCIE-8A-C+E [10GbE]
• Chelsio® S310X-SR-XFP [10GbE]
• Neterion® Xframe® II & Xframe E
[10GbE]
• Alacritech® SES2104ET (drivers: SNP 9.1.0.1092
& 7.3.1.0)
• Alacritech SES2102ET (drivers: SNP 9.1.0.1092
& 7.3.1.0)
• QLogic® 4010C, 4052C, & 4062C |
|
Operating
Systems Supported: |
•
Windows® Vista® 32-bit & x64
(Ultimate & Enterprise) with Built-in iSCSI
initiator
• Windows Server 2003® 32-bit & x64 SP1
(Standard & Enterprise)
with v2.07 iSCSI initiator
• Windows Server 2003 R2 32-bit & x64 (Standard
& Enterprise)
with v2.07 iSCSI initiator
• Windows XP Pro 32-bit & x64 with v2.07 iSCSI
initiator
• Windows 2000 Advanced Server with v1.6 &
v2.01
iSCSI initiator
• Red Hat® 7.3
• Red Hat Enterprise AS update 5
• SuSE® Enterprise Server 10.2 32-bit (x86)
• SuSE Professional 9.3 32-bit & x64
• Mac OS® X (10.4 & 10.5) |
iSCSI
Network Interface
|
iSCSI
Network Interface:
|
|
•
Four 1GbE Copper Ports |
|
Host
Interface:
|
•
iSCSI Draft 20 compliant initiator |
|
Connections:
|
•
1,024 hosts |
|
CHAP
Authentication:
|
•
Yes |
|
Access
Control of Management:
|
•
Yes |
|
iSCSI/TCP/IP
Full HW Offload:
|
•
Yes |
|
Jumbo
Frames Support:
|
•
Yes |
|
Link
Aggregation Group Support:
|
• Yes – Up to four LAGs
(IEEE802.3ad Link Aggregation Group) |
|
VLAN
Support: |
•
Up to four 1-to-1 mapping between IP subnet and VLAN.
Multiple VLANs per physical port with VLAN
tag. All physical ports in LAG belong to
same VLAN (IEEE802.1Q Tag) |
Volume
& RAID Support
|
RAID
Controller:
|
|
•
Single- Integrated in ASIC |
|
RAID
Support:
|
•
RAID Levels 0, 1, 1+0 and 5 |
|
Volumes:
|
•
1,024 Virtual Volumes (256 accessible per initiator) |
|
Target
Nodes:
|
•
1,024 |
|
Online
Capacity Expansio:
|
•
Yes |
|
Hot
Swappable Drives:
|
•
Yes |
|
Instant
Volume Access:
|
•
Yes |
|
Free
Space Defragmentation:
|
• Yes |
|
Auto-Detection
Failed Drive: |
•
Yes |
|
Auto-Rebuild
Spare Drive: |
|
•
Yes |
|
RAID
Level Migration: |
•
Yes |
|
Drive
Roaming in Power Off
(configured
drives are not bay-specific): |
•
Yes |
|
Micro
Rebuilds: |
•
Yes |
Storage
Management
|
Embedded
IP-Based
Management
GUI: |
|
•
Create, manage, expand and monitor storage pool,
volumes and RAID
• Event manager to view and persist events |
|
Firmware
Field Upgradeable: |
•
Yes |
|
SMI-S
Version
1.1: |
•
Yes |
Power
|
Supply
Type: |
|
•
1U 200 Watt |
|
Input
Voltage: |
•
100-240 VAC |
|
Input
Frequency: |
•
50-60Hz |
|
Input
Current: |
•
4A |
|
Power
Factor Correction: |
•
95%@110V, Full load |
|
Power
Consumption: |
•
112 Watts (full configuration) |
|
Thermal: |
•
815 BTU/hour (full configuration) |
Environmental
|
Operating
Temperature: |
|
•
32° to 104°F (0° to 40°C) |
|
Storage
Temperature: |
•
-4° to 158°F (-20° to 70°C) |
|
Operating
Humidity: |
•
20% ~ 90% (Non-condensing) |
|
Storage
Humidity: |
•
10% ~ 95% (Non-condensing) |
Physical
(approximate)
|
Form
Factor: |
|
•
Tower |
|
Dimesnsions
(D x W x H): |
•
10.7in x 6.6in x 10.2in (273mm x 167mm x 259mm) |
|
Weight
with No Drives Installed: |
•
8.8 lbs (4.0 kg) |
International
Approvals
|
Emissions: |
|
•
CE Class A, FCC Class A, C-Tick Class A, VCCI Class
A |
|
Safety: |
•
CSA 60950-1, UL60950-1, IEC 60950-1, EN 60950-1 |
Warranty
and Support
|
Warranty: |
|
•
2-Year Limited* |
|
Extended
Warranty: |
•
Available |
|
Support: |
•
1 year, 9 hours per day / 5 days per week Technical
Support |
Available
Configurations
|
DSN-1100-10: |
|
•
xStack Storage® 4X1GbE iSCSI SAN Array
with 5 SATA Bays |
|
For additional information, options and pricing about our ThinkCP™ products,
please contact our sales representatives - (800)726-2477
or
email - SalesDesk
AT ThinkCP.com
Copyright © 1997 - 2010 H. Co. Computer Products. All Rights Reserved. ThinkCP™
and H. Co. Computer Products™ are trademarks or registered trademarks of
H. Co. Computer Products, Inc. For additional information regarding our trademarks,
please visit Trademark Info at http://www.ThinkCP.com. This list is not intended
to be an all-inclusive or comprehensive list of all H. Co. Computer Products trademarks
and/or intellectual properties. Other product names used herein are for identification
purposes only and may be the respective property or trademarks of other companies.
 |
|
|